Table 7 Performance comparison of the existing works

From: Person authentication based on eye-closed and visual stimulation using EEG signals

Authors

Acquisition protocol

Type of EEG devices

Wired or wireless

Session

Duration

Performance measure

Ma et al. [18]

Resting-state (EO and EC)

Research/clinical

Wired

1

55 s for each task

Accuracy: 64–88%

Armstrong et al. [14]

ERP (word items)

Research/clinical

Wired

3

Not mentioned

Accuracy: 82–97%

Maria et al. [20]

ERP (images)

Research/clinical

Wired

1

1 and half hour

Accuracy: 100%

Sabeti et al. [21]

− Resting-state with EO

− ERP (audio)

Research/clinical

Wired

1

− 2 min

− 20 min

Accuracy:

EC: 38.20–77.53%

ERP: 23.76–99.06%

Proposed method

− Resting-state with EC

− ERP (word items)

Consumer

Wireless

2

− 30 s

− 4 min

Accuracy:

EC: 83.7–96.42%

ERP: 87.64–99.06%