Skip to main content

Table 7 Classification accuracy, specificity and sensitivity for the rest tremor analysis

From: Telemonitoring Parkinson’s disease using machine learning by combining tremor and voice analysis

Used

2-level classification

5-level classification

Classifier

Accuracy

Specificity

Sensitivity

Accuracy

Specificity

Sensitivity

kNN

98.5

100

94.0

90.5

96.0

87.5

SVM

96.8

98.0

92.0

87.0

91.0

86.5

Naive Bayes

91.6

95.5

89.5

77.0

72.0

81.5